SZUSTER system for Engineers

The SZUSTER System innovative products are a great solution designed for Engineers.

Ball check valves

szuster-system-zawor-zwrotny

1.

Fully open position and constant local resistance coefficient starting from the flow rate of 0.7 m/s. Read the article Check valves for sewage pumping stations including fecal matter, which includes a comparison chart of local resistance coefficients of the SZUSTER system ball check valves and traditional valves.

2.

Reduction of vibrations making system work more quietly. Reduction of the noise level in a pumping station is described in the case study on the example of municipal sewage pumping station in Szczecin (Poland), where a traditional valve was exchanged to the SZUSTER system ball check valve.

EKON, EKOS columns

szuster-system-kolumny-ekon-ekos

1.

Complete servicing only from the ground level. Read the article Safety and hygiene aspects of the operation of a sewage transportation system, which emphasize the importance of preserving safety rules, especially in the context of the occurrence in sewage systems of the deadly gas, ie. hydrogen sulphide and methane.

2.

Reduced construction footprint and lack of need for a branch in the discharge pipe for the drain well. These aspects are particularly important in the case of a dense municipal network, which should be adapted to the existing building.

EDP dry pumping stations

przepompownia ścieków

1.

Limiting the dead retention space to a minimum and thereby minimizing occurence of odors. Watch the video, which presents the EDP dry pumping station operation principle and construction.

2.

The possibility of using any manufacturers pumps, which offers pumps with an external cooling jacket.

3.

The possibility of installation in close proximity with residental buildings or outbuildings. By reducing the formation of odors EDP dry pumping station can be located in heavily urbanized areas.

EPP pneumatic pumping stations

szuster-system-blog-pneumatyczna-tlocznia-sciekow

1.

Refresh pumped sewage and prevent putrefying during transport.

2.

Possibility to pump sewage over very large distances and/or heights (working pressure 8-10 bars). By using compressors is possible to use EPP pneumatic pumping station in places where so far it was not possible due to distance and/or height. Through the use of pneumatic sewage pumping station it is possible to build one device instead of a cascade of several pumping stations.

3.

The possibility of installation in close proximity with residental buildings or outbuildings.